Mutable Instruments — Branches


Branches Manual (PDF)


Mutable Instruments Branches – Cheat Sheet

Dual Bernoulli Gate
Purpose: Route incoming triggers/gates to one of two outputs with voltage-controllable probability, or as a toggle/latchable switch.


Input/Output & Controls Reference

Label Type Description Voltage Range
IN (1, 2) Input Jack Trigger/gate input (Section 2 normalled to Section 1) Standard trigger/gate
PROB CV (2) Input Jack CV for probability control (per section) 0V–5V
OUT A (3) Output Jack Trigger/gate output "A" +5V
OUT B (4) Output Jack Trigger/gate output "B" +5V

Knob:
- Probability Knob (A): Adjusts probability between outputs A and B (higher = more to A).
- Counterclockwise: Output B only
- Center: 50/50 random
- Clockwise: Output A only

Button:
- Switch (B):
- Quick press: Toggle "Toggle Mode" (output flips only when tails).
- Hold (>1s): Toggle "Latch Mode" (output stays high until next trigger on opposite output).


Modes


Power and Other Specs


Useful Links